Particle and Aerosol Research
Vol. 16, No. 4, December 2020, Pages 131-140
|
ISSN : 1738-8716 (Print)
ISSN : 2287-8130 (Online)
|
Measurement and analysis of PM10 and PM2.5 from chimneys of
coal-fired power plants using a light scattering method
Dongho Shin1),2), Younghun Kim1),2), Kee-Jung Hong1), Gunhee Lee1), Inyong Park1), Hak-Joon Kim1), Yong-Jin Kim1), Bangwoo Han1) *, and Jungho Hwang2) *
1)Department of Environmental Machinery, Korea Institute of Machinery & Materials, Daejeon
2)Mechanical Engineering, Yonsei University
*Corresponding author.
Tel.: +82-42-868-7068, +82-2-2123-2821, E-mail: bhan@kimm.re.kr, hwangjh@yonsei.ac.kr
Received 11 December 2020, Revised 23 December 2020, Accepted 23 December 2020, Available online 31 December 2020
https://dx.doi.org/10.11629/jpaar.2020.16.4.131
Abstracts
Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine
particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it
is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this
study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on
six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle
size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode
were 0.5 and 1.1 ¥ìm. In addition, it was compared with the gravimetric measurement method, and it was determined
that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument
was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the
concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from
the chimney increased in the form of an exponential function according to the amount of power generation.
Keywords
Dilutor, Optical particle counter, coal-fired power plant, power generation, PM10
File
05. ³í¹® 16±Ç4È£ (½Åµ¿È£)-1Â÷¼öÁ¤.pdf
Download